|
|
|
|
Isolator-4000-895 |
|
Technology Introduction
Possible contamination due to exposure of clean-room environment or personnel to process media can be unacceptable in high toxic applications. An Isolator unit under light vacuum (100 Pa) that provides uncompromised and continuous isolation of its interior from the external environment is necessary in this case. |
Isolator Types |
|
API Isolator |
Formulation Isolator |
Dispensing & Sampling Isolator |
Granulation Isolator |
Reactor Charging Isolator |
QC Isolator |
ANFD Discharge Isolator |
Milling & Sieving Isolator |
Centrifuge Isolator |
Pack off Isolator |
Reaction, Distillation, Filtration & Drying Isolator |
|
|
|
|
Benefits: Operator safety, Uncontaminated process media, Alarms and safety measures in case of breach
|
Applications |
|
Micronizers, Multi-milling, Pulverising, Jet Milling,
Sieving and Weighing |
Toxic Argochemical applications
(Negative Pressure Isolators) |
Handling Cytotoxic drugs |
Oncology drugs and Pack-off |
Sterile applicatins |
Tablet presses and coaters |
Dispensing and Sampling |
Tray Drying (VTD's) |
Roll Compactors |
Pilot plant and laboratory equipment |
Filter Dryers and Fluid Bed Dryers (FBD's) |
|
|
|
|
|
|
|
MTCF-4000-747 |
|
Technology Introduction
Carbon is a pyre-hazardous material that poses a significant risk to operators involved in filtering and cleaning equipment. With this filter, the filtering and cleaning process involves Safety, Cleanliness and Timeliness.
In Leaf filter the carbon should be removed manually every time where as in Multi Tube Carbon Filter, the discharge is automatic and the carbon is directly discharged into the tub without any manual handling.
Filtrate is pumped into filter, mother liquor is sent to ML tank and solid is collected on filter candle(s). By reverse flush method, wet cake is discharged and collected in to a tub kept right below the filter. |
|
|
|
|
|
RSS-4000-692 |
|
Technology Introduction
Taking a sample at high temperature is a major cause of worry for pharmaceutical plants especially when the reaction is hazardous, Spillover and exposure of sampling liquid is a perennial cause of batch rejection, reprocessing and various quality-related issues ultimately leading to personnel risk and loss of profits.
Pre-dedded quantity of sample can be directly pulled into the sampling container in a closed manner Operator can see what is happening inside the sampling pot clearly and is always In control, but never at risk. Cleaning is easier, faster and risk-free.
|
|
|
|
|
|